Description
The 6000 Series low energy operator is a heavy-duty unit designed for rigorous, high-use applications. Built-in intelligence enables the operator to safeguard users while providing better door control. Simple installation and adjustment features combined with the unit’s high level of versatility allows for seamless integration with a multitude of facilities and systems.
Features
Adjustable Hold Open – Amount of time a door will stay in the full open position after an activation
Blow open for smoke ventilation – Door opens when signal is received from alarm system allowing air or smoke to flow through opening. Door will stay open until signal from alarm system is stopped
Infinite Hold Open – Door will hold open at set position until power is turned off
Obstruction Detection – Open: door closes if it hits an obstruction while opening. Close: door reopens (once) if it hits an obstruction while closing. If it hits the obstruction again, the door will rest against the obstruction until it is removed
Open Delay – Delays operator opening for locking hardware
Overload Safety Shut-Off – After 3 minutes of receiving a door activation signal, inverter times out and door closes – Prevents motor/inverter damage
Presence Detector Input – Input for external sensor to detect presence at door open or close position only
Push & Go – As the door is manually opened, the operator “senses” movement and opens door to the full-open position
Selector mode switch – Off: Disables signal inputs unless Blow Open is activated. On: Activates signal inputs. Hold Open: Activates the unit (unless blow closed is activated on 6300) to the hold open position
Two Selectable Output relay – Multi-function relay outputs
Vestibule Delay – When the push button is pressed, first door in vestibule will open. Second door will open once vestibule door delay has expired. Delay is adjustable
ANSI/BHMA A156.19 certified & ADA Compliant
Specifications
Construction
Heavy-Duty cast-aluminum body
Function
Hydraulic Electronic Door Operator
Interior or Exterior
Both
Handing
Non-Handed
Power Input
120 VAC, 60Hz
Power Supply
24 VDC (1.3A)
Finish
689 – Aluminum
Maximum Door Weight
250lbs
Door Width
36″ – 48″
Housing Projection
4-3/4″
Housing Height
5-3/16″
Housing Length
37-1/2″
Mounting Style
Push Side
Max. Door Opening
110 Degrees
Certifications
» ANSI/BHMA A156.19 certified
» ETL tested to UL / cUL standards for automatic doors used on fire and smoke barrier doors and CSA C22.2 No. 247 for operators and systems of doors
» UL10C listed for positive pressure fire test
» Comply with requirements for the Americans with Disabilities Act (A.D.A)
» California State Fire Marshall Listing 3266- 0944:0110
» Manufactured in an ISO 9001 and ISO 14001 facility
» Verified by Green Circle to offer the following energy savings as compared to similar products:
» 19% efficiency
» Health product declaration and UL certified environmental product declaration
Warranty
2-Year Limited Warranty