Dahua / Scalable Networked Access Control Panel / Enclosed / 4 Readers / TCP / RS-485 / 100K Users / 150K Event History / 9-15VDC / ASC1204C

$465.59

DH-ASC1204C

SKU: DH-ASC1204C-delete Category: Tag:

Description

DH-ASC1204C

The DH-ASC1204C Four-Door, One-Way Access Controller is a controlling device which compensates video surveillance and visual intercom. It has neat and modern design with strong functionality, suitable for commercial building, corporation property and intelligent community.

Features:

Includes vented enclosure and pre-wired power supply

Removable terminal blocks support ease of wiring

Scalable up to 64 four-door controllers managed by SmartPSS

Supports controlled lock down of all connected access doors

Easily integrate biometrics to secure sensitive locations

Enable anti-passback and multi-door interlock to control traffic in high security applications

Specifications:

System

Main Processor

32-bit ARM Cortex-M3

Memory

16 MB (32 MB external)

Input/Output Ports

Inputs:

Nine (9) Normally Open, Supervised Inputs, 0 VDC to 5 VDC nominal: Maximum Power for Relay Input, Four (4) Door Sensors, Four (4) Exit Buttons, One (1) Alarm

Outputs:

Five (5) Dry Relays: Four (4) Lock Relays Form C, 3 A at 24 VDC maximum¹, One (1) Alarm Relay, Switching Signal Type. 1 A at 24 VDC maximum

Readers

Four (4) Reader Inputs 11 VDC to 13 VDC, current limited. 300 mA, maximum per port

Capacity

Card Holders

100,000

Events

150,000

Functions

Unlock Modes

Card, Fingerprint, Password, Card + Password, Card or Password, Card + Fingerprint, Fingerprint + Password, and By Period

User Management

General, VIP, Guest, Patrol, Black List, Duress

Alarm Function

Door time-out Alarm, Intrusion Alarm, Duress Alarm, Tamper Alarm

Schedule Settings

Schedule: 128 Groups
Period: 128 Groups

Interface

Wiegand Reader Data

24 AWG, 5 conductor stranded cable without shield, 40.0 m (131.23 ft), maximum

RS485 Reader Data

24 AWG, 120 Ω Impedance, 3 conductor stranded cable without shield, 100.0 m (328.08 ft) maximum. Use a separate power supply to extend the RS485 reader data up to 1000.0 m (3280.84 ft), maximum

Network Compatibility

TCP/IP, RJ-45 (10/100 Mbps)

Operations

Power Supply

Power Cable Included

Primary Voltage Input

100 VAC to 240 VAC, 1.5 A, 47 Hz to 63 Hz

Secondary Voltage Input

9 VDC to 15 VDC, 500 mA

Battery Charging Circuit

13.8 VDC at 1 A. Use only a 12 VDC, 7000 mAh sealed rechargeable lead acid type battery (includes one 11-in. battery cable)³

RTC

Support

Dimensions

11.02 in. x 12.60 in. x 4.49 in.

Certifications

Safety

UL 60950-1 & CAN/CSA C22.2 No. 60950-1-07
EN 60950:2006+A2:2013

Electromagnetic
Compatibility (EMC)

FCC CFR 47 Part 15 subpart B. EN

 

Downloads:

Spec Sheet

User Manual

Quick Installation Guide