Description
Smart Self-Diagnosing Power Supply
PSMEL200
Operates a pair of doors with two low current exit devices simultaneously or independently control two single door leaf’s.
Shall operate up to two (2) 24VDC panic hardware devices simultaneously
Each lock output shall have an adjustable relock delay timer
It shall control a pair of doors simultaneously or independently two doors
Relay for each output to trigger external relays, ADA push plate switches, etc.
Delayed follower relays shall control automatic door operators for doors that are always locked or for doors that are unlocked during the business day
Two un-switched auxiliary voltage outputs shall provide/remove power to the lock outputs when activated
A programmable FACP interface shall provide power/remove power to the lock outputs when activated
Shall have LED status indicators monitor AC, FACP status & for lock output wiring supervision
Intelligent logic shall provide protection against accidental shorting of lock outputs
Specifications
Smart Visual Indicators
• Output 1 & 2 = Red (ON) input LEDs indicate panic device status is energized (rapid blink/short or over current) (slow blink/open circuit)
• FAI = Green (ON) FACP Input Triggered (Alarm Condition)
• Battery Trouble = Red (ON) Battery Normal (slow blink/bad battery or no battery)
• AC Trouble = Green (ON) AC normal (slow blink/AC low or missing)
Visual Indicators
• Output 1 (On/Over/Open)
• Output 2 (On/Over/Open)
• FAI (On/Off)
• Battery (On/Off)
• AC Trouble (On/Low or Missing)
• AC Power (On/Off)
Battery Backup
• Built-in charger for sealed lead acid or gel type batteries
• Automatic switch over to stand-by battery when AC fails
• Maximum charge current .65 amps
• 4AA batteries will make emergency stand-by at least 30 minutes
Input
•
Input 115VAC 60Hz, 2.5 amp or 230VAC, 50Hz, 1.5 amps
• Two (2) N.O. Trigger Inputs
Outputs
• Two (2) 24 VDC individually controlled lock outputs rated @ 1 amp each. Load connected not to exceed 1 amp.
• One (1) 24VDC @ .08 amps filtered regulated auxiliary output. (Not affected by FACP trigger)
• One (1)12 VDC @ .05 amp filtered regulated auxiliary output. (Not affected by FACP trigger) Note: Total combined current for the 24VDC outputs may not exceed 1.75 amp.
• Two (2) follower N.O. outputs for controlling ADA actuators/ accessories
• Two (2) momentary operator activation outputs
• Trouble output relay for indicating low/AC Voltage and battery trouble.
Dimensions
13″ x 12.5″ x 3.5″ (H x W x D)
Code / Agency Listings
• UL File for Access Control Systems Units (UL 294)
• CUL Listed – CSA Standard C22.2 No. 205-M983, Signal Equipment’s
• CSFM – California State Fire Marshal Approved